Distributed strain sensing to assess corroded RC beams

Abstract

Corrosion of reinforcing steel reduces the capacity of reinforced concrete structures by reducing the reinforcement area and decreasing the bond between the reinforcement and the surrounding concrete. Currently the assessment of reinforced concrete structures is based largely on visual inspections, which do not provide quantitative data about structural behaviour. This research program investigates the use of distributed fibre optic strain sensors to measure the effects of corrosion on reinforced concrete beam behaviour. Six beams with varying levels of corrosion are instrumented with fibre optic sensors and tested in three point bending. The percentage of reinforcement area lost due to corrosion has a disproportionate impact on the percentage reduction in beam capacity, however these results are a function of the testing parameters and may not be applicable to structures in the field. The fibre optic measurements are used to identify regions of reinforcement-concrete bond loss and the effect of that bond loss on beam behaviour.

Description

The final publication is available at Elsevier via https://doi.org/10.1016/j.engstruct.2017.03.013 © 2017. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/

Keywords

Fiber optic sensors, Strain measurement, Reinforced concrete, Corrosion

Citation

Davis, M., Hoult, N. A., & Scott, A. (2017). Distributed strain sensing to assess corroded RC beams. Engineering Structures, 140, 473-482

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwised noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 International